Product name: hot gas efficient environmental protection products
A. Structure features:
1. The coal into gas combustion (secondary combustion), there is no phenomenon of smoke, smoke depth of 50-70 mg, achieve discharge standards.
2. To produce fuel can be saved about 5%, save power consumption about 10-30%, achieve saving energy and reducing consumption.
3. Add fuel available for 30 to 60 minutes at a time, reduce the labor intensity of operation work, fewer fuel due to the working environment is improved at the same time.
4. Because the gas is inflammable, explosive, so the increase in the design of ignition advance, as long as according to the operation manual operation, like a family with a gas stove, gas furnace) as safe and reliable.
5. The fan can control motor frequency conversion adjustment according to the requirements of the user's controller, using power to achieve the best effect.
6. The air supply system are equipped with control of the valve, to ensure that during the operation according to the requirement of the user to use fire at any time to adjust.
7. Under the grate ash chamber to increase the pool of water sealing, which can realize the function of safe water seal. Still can make slag out of falling into a pool, facilitate clear ash, because it is wet ash discharge, no dust float in the sky, the operating environment and conditions improved step temple.
8. Top of the gas stove has one or two dozen known, convenient in gas stove of coking coke.
2. Process
Technological process of the system is: will the combustion chamber of the stove fire, until a flame, Canon of peroxide to lighting a gas stove - coal in the furnace, reduction, carbonization, after drying and air mixed gas - into the combustion chamber - gas furnace flame lit - began to burn.
model
|
RMQ400
|
RMQ500
|
RMQ600
|
RMQ700
|
RMQ800
|
RMQ900
|
RMQ1000
|
Chamber of a stove or furnace inner diameter(mm)
|
400
|
500
|
600
|
700
|
800
|
900
|
1000
|
Furnace area(㎡)
|
0.126
|
0.196
|
0.282
|
0.384
|
0.502
|
0.635
|
0.785
|
Water jacket heating area(㎡)
|
2.73
|
3.42
|
4.1
|
4.79
|
5.46
|
6.15
|
6.84
|
Applicable to coal
|
Don't glue or weak bonding anthracite, bituminous coal or coke. Coal quality shall conform to the requirements of the GB9143
|
Ash layer height(mm)
|
100~200
|
100~200
|
100~200
|
100~200
|
100~200
|
100~200
|
100~200
|
The granularity of coal(mm)
|
|
|
13~25
|
25~50
|
50~100
|
|
|
Coal consumption(kg/h)
|
10~20
|
30~40
|
50~60
|
70~80
|
90~100
|
120~140
|
150~180
|
The gas production(Mm3/h)
|
30~60
|
90~120
|
100~180
|
210~240
|
270~300
|
360~420
|
450~540
|
The gas heating value(KJ/m3)
|
5020~6060
|
5020~6060
|
5020~6060
|
5020~6060
|
5020~6060
|
5020~6060
|
5020~6060
|
The gas outlet temperature(℃)
|
400~550
|
400~550
|
400~550
|
400~550
|
400~550
|
400~550
|
400~550
|
Feeding way
|
manual
|
The fan motor power(kw)
|
2.2
|
2.2
|
3
|
3
|
4
|
5.5
|
7.5
|
The fan pressure(Pa)
|
1139
|
1139
|
1439
|
1439
|
1668
|
2491
|
2986
|
The fan flow(m/h)
|
1146
|
1146
|
1539
|
1539
|
2550
|
3212
|
5113
|
Slag discharge form
|
Wet, automatic slag discharge
|
|